Evaluation of Load-Bearing Capacity in Japanese Arch Steel Aqueduct Bridge through Structural Redundancy Assessment

Nima Mohammadi; Yasuko Kuwata1

1

Publication Date: 2024/10/29

Abstract: Structural redundancy assessment of steel aqueduct bridges is made by the analysis of a case study using the Musota Aqueduct bridge structure: a simply supported steel arch bridge erected in 1973 and a seven- span continuous steel aqueduct bridge. In this paper, as a case study, after the validation of the model, the structural redundancy of the Musota aqueduct bridge in Wakayama City with respect to its load-carrying capacity after the failure of hanging components due to corrosion was investigated. The conventional procedure for the assessment of redundancy makes use of static nonlinear structural analysis. A three-dimensional finite-element model of this bridge was developed to simulate its behavior. The results from the linear analysis are compared with those from the nonlinear analysis to investigate the appropriateness of the former in the evaluation of redundancy. A detailed nonlinear static finite element study is carried out into the hangers' components of the arch bridge in order to clarify the implications involved in the failure of redundancy. Finally, recommendations for prudent bridge maintenance methods are presented based on findings from the investigation.

Keywords: Redundancy Analysis, Load Capacity, Hangers, Arch Aqueduct Bridge, Damage.

DOI: https://doi.org/10.38124/ijisrt/IJISRT24OCT807

PDF: https://ijirst.demo4.arinfotech.co/assets/upload/files/IJISRT24OCT807.pdf

REFERENCES

  1. F. Yamazaki, W. Liu, T. Furuya, and Y. Maruyama, “Assessment of Aqueduct Bridge Failure in Wakayama City, Japan, Based on Uav Surveying Flights and High-Resolution Sar Data,” Int. Geosci. Remote Sens. Symp., vol. 2022-July, pp. 497–500, 2022, doi: 10.1109/IGARSS46834.2022.9883792.
  2. K. Kinoshita, T. Kumura, Y. Yamaguchi, and T. Tanaka, “Anomalous Displacement Detection of Bridges Using Satellite SAR: A Case Study on a Collapse of Musota Water Pipe Bridge,” Int. Geosci. Remote Sens. Symp., vol. 2023-July, pp. 1720–1723, 2023, doi: 10.1109/IGARSS52108.2023.10283463.
  3. N. Mohammadi, Y. Kuwata, and A. Morioka, “Observation monitoring and modal analysis of aqueduct bridge considering corrosion: a case study of the Musota Aqueduct Bridge,” J. JSCE, vol. 12, no. 2, pp. 23–13137, 2024, doi: 10.2208/JOURNALOFJSCE.23-13137.
  4. M. Ghosn and F. Moses, “NCHRP Report 406: Redundancy In Highway Bridge Superstructures,” Onlinepubs.Trb.Org, p. 44, 1998.
  5. S. Hao, “I35W Bridge Collapse: Lessons Learned and Challenges Revealed,” Struct. Congr. 2011 - Proc. 2011 Struct. Congr., pp. 3153–3170, 2011, doi: 10.1061/41171(401)275.
  6. M. of Wakayama Office of River and National Highway and T. and T. Land, Infrastructure, Failure scene of an aqueduct bridge from a fixed-point camera, (2021).
  7. S.-S. Li, G.-Y. Sang, M.-Y. Xu, and Y. Ye, “Different Aqueduct Structure Make and Design,” Mater. Environ. Eng., pp. 1177–1184, Oct. 2017, doi: 10.1515/9783110516623-115/HTML.
  8.  “API STD 1104: Welding of Pipelines and Related Facilities,” vol. 22, 2021.
  9. L. K. Sing, S. N. A. Azraai, N. Yahaya, L. Zardasti, and N. Md Noor, “Strength development of epoxy grouts for pipeline rehabilitation,” J. Teknol., vol. 79, no. 1, 2017, doi: 10.11113/jt.v79.9339.
  10. M. Shamsuddoha, M. M. Islam, T. Aravinthan, A. Manalo, and K. tak Lau, “Effectiveness of using fibre-reinforced polymer composites for underwater steel pipeline repairs,” 2013. doi: 10.1016/j.compstruct.2012.12.019.
  11. A. Diniță et al., “Advancements in Fiber-Reinforced Polymer Composites: A Comprehensive Analysis,” 2024. doi: 10.3390/polym16010002.
  12. D. R. Mertz and U. S. F. H. A. O. of B. Technology, Steel Bridge Design Handbook: Redundancy. United States. Federal Highway Administration. Office of Bridge Technology, 2012. doi: 10.21949/1503647.
  13. D. M. Frangopol and J. P. Curley, “Effects of Damage and Redundancy on Structural Reliability,” J. Struct. Eng., vol. 113, no. 7, pp. 1533–1549, Jul. 1987, doi: 10.1061/(ASCE)0733-9445(1987)113:7(1533).
  14. Hazus, Hazus–MH 2.1: Technical Manual. 2012.
  15. Caltrans, “Memo to Designers 12-2: Guidelines for Identi-fication of Steel Bridge Members.,” 2012.
  16. R. Pekelnicky and C. Poland, “ASCE 41-13: Seismic Evaluation and Retrofit Rehabilitation of Existing Buildings,” Citeseer, 2012, doi: 10.1016/j.aqpro.2013.07.003.